 Next: Acknowledgements
Up: ESP   Extended Surface Photometry
 Previous: Output file formats
 
 
 
The software written for the HISTPEAK application contains routines that generate 
a wide range of statistical quantities concerning the pixel values in
an image. Clearly then, some users writing their own software might want to 
incorporate such routines into their own code. To make this easier to acheive 
the salient parts of HISTPEAK have been made into an application HSUB wherein
HISTPEAK (in a slightly modified form) is called from the main subroutine.
The subroutine called HISTPEAK2 should obtain values for all the 
quantities displayed by HISTPEAK (various modal pixel values, standard 
deviation, kurtosis, absolute deviation, number of bad pixels etc.) and these 
can be passed to the the main routine if required. HSUB as it stands allows you 
you to define which type of modal pixel value should be estimated
(there are four to choose from -- see HISTPEAK) and displayed, but this
is merely intended to show how the routine HISTPEAK2 might be used.
The code is fully commented to make its use easier.
 
 
 
 
 
 
    
 Next: Acknowledgements
Up: ESP   Extended Surface Photometry
 Previous: Output file formats
 
 
ESP --- Extended Surface Photometry
Starlink User Note 180
Norman Gray
Mark Taylor
Grant Privett
27 January 2000
E-mail:ussc@star.rl.ac.uk
Copyright © 2002 Council for the Central Laboratory of the Research Councils